Acrylic (PMMA) Car LOGO Board Chrome Metalizing System
Summary: The RTEP2215 set metalizing system was custom designed and manufactured for Car LOGO board chrome coating. With the PVD thermal evaporation technology, which deposits thin high reflection film on PMMA (Acrylic) surface, gives outstanding coating layers as shown below: during day time, sign symbols have a solid metal look ( stainless steel effect ); while at night, they are illuminated ( LED light inside is installed ) from front, back and side views.
Type:
Design Features:
Technical Specifications:
1. Ultimate Vacuum Pressure: better than 5.0×10-6 Torr.
2. Operating Vacuum Pressure: 1.0×10-4 Torr.
3. Pumping down Time: from 1 atm to 1.0×10-4 Torr≤3 minutes ( room temperature, dry, clean and empty chamber)
4. Metalizing material ( evaporation): Al, Cr, Sn, Ti, SS, Cu… etc.
5. Operating Model: Full Automatically /Semi-Auto/ Manually
The vacuum coating machine contains key completed system listed below:
1. Vacuum Chamber
1.1 Size: Inner Diameter 2200mm
Inner Height: 1500mm
1.2 Material: Vacuum Chamber SUS304
Door and flanges SUS304
Chamber strengthen structure: SS41 mild steel, with painted finishing surface treatment
Chamber chassis SS41 mild steel with painted finishing surface treatment
1.3 Evaporation Shield : SUS304
1.4 View Window: on chamber door
1.5 Vacuum Chamber Venting Valve (including silencer)
1.6 Door: SUS304 material
2. Rouhging Vacuum Pumping System (Backing Pump Package)- Leybold
3. High Vacuum Pumping System (Diffusion Pump + Cold trap device)- Leybold
4. Electrical Control and Operation System- PLC+ Touch Screen
4.1 Main circuit: None-fuse breaker switch, electromagnetic switch, C/T in series type
4.2 Evaporation Power
4.3 Evaporation Control System
4.4 Operation System: Touch Screen + PLC, recipe control and data logging, Auto shutdown, auto evacuation, auto coating
4.5 Vacuum Pressure Measuring System
Vacuum Gauge: Pirani + Penning gauge
Thermocouple Gauge: 760 Torr ~ 5*10-4 Torr
4.6 Alarm System: Compressed air pressure , Cooling water flow, Mis-operation
4.7 Power Load Indicator: Voltage indicator and load current indicator
5. Deposition System
5.1 Tungsten filament evaporation source
5.2 Cr/Al wires
6. Sub-System
6.1 Air Compressed Valve Control System
6.2 Cooling Water System:Water flow pipe and switch valve system
6.3 Polycold (-120~-145℃) Brooks Cryopump for option.
Compressed Air: 5~8kg/cm2
Cooling Water: Water-In Temperature: 20~25℃, 200 Liter/min,
Water-In Pressure: 2~3 kg/cm2,
Power: 3 Phase 380V 50Hz(60Hz), 100kVA
Installation Area: (L*W*H) 9000*4200*3000mm
Exhaust: Vent for mechanical pumps